BACK
ADTRAN MODULES
GET MARKET VALUE OF ANY SINGLE LINE ITEM ON THIS PAGE
|
Category |
Part Number |
Description |
|
|
SHELVES |
4200023L3 |
16 Position Central
Site Shelf Solution; AC Power w/Controller Card. Is being replaced
by 4202023L1. |
|
SHELVES |
4200023L4 |
16 Position Central
Site Shelf Solution; DC Power w/Controller Card. Is being replaced
by 4202023L3. |
|
SHELVES |
4200023L5 |
16 Position Central
Site Shelf Solution; AC Power w/ SNMP Controller Card. Is being
replaced by 4202023L5. |
|
SHELVES |
4200023L6 |
16 Position Central
Site Shelf Solution; DC Power w/ SNMP Controller Card. Is being
replaced by 4202023L7. |
|
SHELVES |
4202023L1 |
2nd Generation,16
Position Central Site Shelf Solution; Single source AC Power with
Controller Card and single AC supply. |
|
SHELVES |
4202023L2 |
2nd Generation 16
Position Central Site Shelf Solution; Dual feed AC Power with
Controller Card. Two AC Power Supplies included. |
|
SHELVES |
4202023L3 |
2nd Generation,16
Position Central Site Shelf Solution; Single source DC Power with
Controller Card and single DC supply. |
|
SHELVES |
4202023L4 |
2nd Generation 16
Position Central Site Shelf Solution; Dual feed DC Power with
Controller Card. Two DC Power Supplies included. |
|
SHELVES |
4202023L5 |
2nd Generation 16
Position Central Site Shelf Solution; Single source AC Power with
SNMP Controller Card and single AC supply. |
|
SHELVES |
4202023L6 |
2nd Generation 16
Position Central Site Shelf Solution; Dual feed AC Power with SNMP
Controller Card. Two AC Power Supplies included. |
|
SHELVES |
4202023L7 |
2nd Generation 16
Position Central Site Shelf Solution; Single source DC Power with
SNMP Controller Card and single DC supply. |
|
SHELVES |
4202023L8 |
2nd Generation 16
Position Central Site Shelf Solution; Dual feed DC Power with SNMP
Controller Card. Two DC Power Supplies included. |
|
SHELVES |
4202023L6#UPG |
Upgrade for
existing Smart 16/16e shelves to 2nd Generation Smart 16 / 16e with
dual AC power inputs. Includes metal chassis and Dual feed AC Power
Interface card but no controller or power supplies. |
|
SHELVES |
1200045L1 |
Hand-held LCD for
configuration, test of Smart 16/16e Shelf. |
|
SHELVES |
1200048L3 |
Optional AC
redundant power supply for Smart 16 / 16e shelves. |
|
SHELVES |
1200048L4 |
Optional DC
redundant power supply for Smart 16 / 16e shelves. |
|
SHELVES |
1202163L2 |
Dual AC power feed
rear power interface card for 2nd Gen Smart 16 / 16e shelves. |
|
SHELVES |
1202164L2 |
Dual DC power feed
rear power interface card for 2nd Gen Smart 16 / 16e shelves. |
|
SHELVES |
4200162L1 |
SNMP Controller
Card to upgrade existing non SNMP Smart 16 shelves. Includes single
feed AC power rear panel segment. Is being replaced w/ 4202162L1. |
|
SHELVES |
4200162L2 |
SNMP Controller
Card to upgrade existing non SNMP Smart 16 shelves. Includes single
feed DC power rear panel segment. Is being replaced w/ 4202162L3. |
|
SHELVES |
4202162L1 |
SNMP Controller
Card to upgrade existing non SNMP 2nd Gen Smart 16 shelves. Includes
single AC power rear power interface module. |
|
SHELVES |
4202162L2 |
SNMP Controller
Card to upgrade existing non SNMP 2nd Gen Smart 16 shelves. Includes
Dual AC power rear power interface module. |
|
SHELVES |
4202162L3 |
SNMP Controller
Card to upgrade existing non SNMP 2nd Gen Smart 16 shelves. Includes
single DC power rear power interface module. |
|
SHELVES |
4202162L4 |
SNMP Controller
Card to upgrade existing non SNMP 2nd Gen Smart 16 shelves. Includes
Dual DC power rear power interface module. |
|
SHELVES |
1200658L1 |
Front blank panel
for Smart 16 shelf. Used to cover blank slots in a Smart 16 shelf. 8
panels per box. |
|
SHELVES |
1200658L2 |
Rear blank panel
for Smart 16 shelf. Used to cover blank slots in a Smart 16 shelf. 8
panels per box. |
|
SHELVES |
1200061L1 |
19" Rackmount
shelf, houses 2 standalone DSU III AR, ISU 128 or ISU 2x64 products.
Color: Black. |
|
SHELVES |
1200061L2 |
Blank Panel color
matched for 1200061L1 Dual DSU unit shelf. Snap insert, no tools
required. |
|
SHELVES |
1200085L1 |
19" rackmount
enclosure designed to house up to 10 DSU 56/64, DSU 5600, Express
XL, or Express XLT units. Color: Cream. |
|
SHELVES |
1200202L1 |
19" Rackmount
shelf, houses 2 standalone DSU IV ESP, TSU ESP, IQ Series, or ISU
512 (requires new housing) products. Color: Cream. |
|
SHELVES |
1200202L2 |
Blank Panel color
matched for 1200202L1 Dual ESP unit shelf. Snap insert, no tools
required. |
|
SHELVES |
1200088L1 |
19" Rackmount
enclosure designed to house up to 10 TSU LT, TSU ACE, Express L
series, or ISDN NT1 ACE3 units. Color: Cream. |
|
SHELVES |
1202088L1 |
19" Rackmount
enclosure designed to house up to 10 NetVanta 2100, or ISDN NT1 ACE4
units. Color: White. |
|
SHELVES |
1200094L1 |
Hinged, pull-down,
wall mounting shelf for the TSU 600 and ATLAS 800. Provides for
flush mounting of unit to wall, with pull-down access to the units'
front panels. Color: Cream. |
|
SHELVES |
1150028L1 |
19" rackmount T400
shelf with 12 slots; Used to hold 12 T400 NT1 CPs or 10 T400 NT1 CPs
and 1 or 2 1353POWER04 Power Supplies. Rear panel has 3 male 50-pin
micro ribbon connections (1 to network; 2 to customer). |
|
SHELVES |
1150024L1 |
23" rackmount T400
shelf with 14 slots; Used to hold 14 T400 NT1 CPs or 12 T400 NT1 CPs
and 1 or 2 T400 Power Supplies. Shelf may also be powered by an
external supply. |
|
SHELVES |
1150092L1 |
Holds up to 14 T400
Circuit Packs. This unit can be locally powered or span powered
devices may be used. Compatible technologies include T1, FT1, ISDN,
DDS, HDSL and HDSL-2. |
|
SHELVES |
1353POWER04 |
T400 Power Supply,
converts 110 VAC to 48 VDC, 3 amps, for internally powering the 19"
and 23" T400 shelves. 2 units may be used to provide redundancy. |
|
Category |
Part Number |
Description |
|
FRAME RELAY |
1202130L2 |
Dual Port multi-protocol FRAD, includes an integrated 56/64K DSU/CSU.
Two DTE & one DCE EIA-232 (DB25) interfaces built-in, V.35 is
supported but requires either 1200193L1 or 1200194L1 adapter cable(s). |
|
FRAME RELAY |
1202175L1 |
Dual port multi-protocol FRAD/Pt-Pt DDS Mux, supports voice w/
Dual voice cards. Includes integrated 56/64K DSU, DBU supported for
DDS mode w/ESP DBU cards (see Accessories). V.35 requires either
1200193L1 or 1200194L1 adapter cable(s). |
|
FRAME RELAY |
1200208L1 |
Multi-protocol frame access device, includes a 10BaseT ethernet
full IP router port, an EIA-232/V.35 serial port for legacy protocol
support. Includes compressed voice and DBU support. V.35 requires
adapter cable 1200193L1 or 1200194L1. |
|
FRAME RELAY |
1200653L1 |
Quad Foreign Exchange Subscriber end module. Provides Quad voice
ports in FXS or PLAR modes. Includes ring generator. Works in
express 5210 only. |
|
FRAME RELAY |
1202187L1 |
Dual foreign exchange office end card. Provides dual FXO ports.
Works in Expresss 5200 series. |
|
FRAME RELAY |
1202188L1 |
Dual foreign exchange subscriber end card. Provides dual voice
ports in FXS or PLAR modes. Includes ring generator. Works in
Express 5200 series. |
|
FRAME RELAY |
1202189L1 |
Provides dual E&M ports in either 2- or 4-wire modes. Supports
Type I or Type II signaling. Works in Express 5200 series. |
|
FRAME RELAY |
4200208L1 |
Express 5210 Fractional T1 bundle. This bundle includes an
Express 5210 (1200208L1), TSU ACE (1200295L1), ESP DCE DBU Card
(1204006L1) and FSU V.35 Male Adapter Cable (1200193L1). This bundle
can be used in Fractional T1 FRAD applications up to 512 kbps. |
|
FRAME RELAY |
1200193L1 |
V.35 Adapter Cable, 6 ft., male (DB25) to male (V.35) for Express
5100, Express 5200 series and for V.35 support for DCE Card. |
|
FRAME RELAY |
1200194L1 |
V.35 Adapter Cable, 6 ft., male (DB25) to female (V.35) for
Express 5100, Express 5200 series and for V.35 support for DCE Card. |
|
Category |
Part Number |
Description |
|
FIBER |
1200663L1 |
Optical Service
Unit for point to point fiber applications. Ability to support up to
4 DTE ports. Single integrated HSSI port, SCSI-II 50 pin female
connector and three hot swappable option slots, uses T3SU option
modules. Supports SNMP and Telnet access. -48 Vdc. 1310 nm
single-mode laser. SC type connectors. |
|
FIBER |
4200663L1 |
Bundle including
OSU 300 single-mode SC (1200663L1) and 48 VDC AC/DC power supply
(1200470L1). |
|
FIBER |
1200663L4 |
Optical Service
Unit for point to point fiber applications. Ability to support up to
4 DTE ports. Single integrated HSSI port, SCSI-II 50 pin female
connector and three hot swappable option slots, uses T3SU option
modules. Supports SNMP and Telnet access. -48 Vdc. 1310 nm
multi-mode ELED. ST type connector. |
|
FIBER |
4200663L4 |
Bundle including
OSU 300 multi-mode ST (1200663L4) and 48 VDC AC/DC power supply
(1200470L1). |
|
FIBER |
1200664L1 |
DS3/STS-1/E3 to
fiber converter for use on point to point fiber. Supports DS3, STS-1
and E3 electrical interfaces. Optical interface is a 1310 nm,
single-mode laser with SC type connectors. -48 Vdc |
|
FIBER |
4200664L1 |
Bundle including
OCU 45 single-mode SC (1200664L1) and 48 VDC AC/DC power supply
(1200470L1). |
|
FIBER |
1200664L4 |
DS3/STS-1/E3 to
fiber converter for use on point to point fiber. Supports DS3, STS-1
and E3 electrical interfaces. Optical interface is a 1310 nm,
multi-mode ELED with ST type connectors. |
|
FIBER |
4200664L4 |
Bundle including
OCU 45 multi-mode ST (1200664L4) and 48 VDC AC/DC power supply
(1200470L1). |
|
FIBER |
1200233L1 |
Includes 2 Vertical
Mounting brackets for OCU 45, used to attach OCU 45 to 19"/23"
Vertical Mounting Bars. Used in conjunction with 1200469L1 and
1200469L2 OCU 45 Vertical Mounting Bars. |
|
FIBER |
1200233L2 |
One pair of
wall-mount brackets for OCU 45. |
|
FIBER |
1200468L1 |
Mouting tray for
OCU 45. Allows 2 OCU 45 to be mounted side by side in a 19" rack.
1200293L1 can be used to extend the Mounting Tray to fit 23" racks. |
|
FIBER |
1200469L1 |
Includes 2 19"
Vertical Mounting bars for OCU 45, used to mount upto 10 OCU 45s in
4U of space in a 19" rack. Used in conjunction with 1200233L1 OCU 45
Vertical Mounting Brackets. |
|
FIBER |
1200469L2 |
Includes 2 23"
Vertical Mounting bars for OCU 45, used to mount upto 12 OCU 45s in
4U of space in a 23" rack. Used in conjunction with 1200233L1 OCU 45
Vertical Mounting Brackets. |
|
FIBER |
1200470L1 |
90-240VAC, 50/60Hz
auto-ranging power supply to be used w/ the DC versions of the T3SU
300, MX2800, OSU 300 and OCU 45. US power cord provided. |
|
Category |
Part Number |
Description |
|
T1 |
1202022L1 |
T1 Channel Service
Unit used for interfacing CPE equipment to a T1 line. Line powered
or may be powered by included AC wall plug. Unit is transparent to
ESF and B8ZS. New housing with LEDS on front of unit and interfaces
on rear of unit. |
|
T1 |
1902022L1 |
12VDC power supply.
Converts 120 VAC, 60 Hz power to 12 VDC for T1 CSU ACE (1202022L1). |
|
T1 |
1203025L1 |
T1 ESF CSU used for
interfacing CPE equipment to T1 line. Also provides SF to ESF
conversion. Support for T-Watch and updated menu structure. |
|
T1 |
1202066L1 |
Rackmount version
of ESF CSU ACE compatible with Smart 16 /16e shelves. Used to
interface CPE equipment to T1 line. Provides SF to ESF conversion
with full ESF performance information. |
|
T1 |
1210018L1 |
Type 400 T1 Channel
Service Unit Circuit Pack, used for interfacing CPE equipment to a
T1 line. Compatible with T400 shelves (1150024L1, 1150028L1). |
|
T1 |
1200295L1 |
Low cost, single
port T1/FT1 DSU/CSU with LCD display and front panel, 4 button
keypad. Single V.35 connector. Supports remote
configuration/monitoring across the FDL or 8K inband from host TSU
LT or TSU ESP. No test jacks. |
|
T1 |
1202060L1 |
Low cost, single
port T1/FT1 DSU/CSU with LCD display and front panel, 4 button
keypad. VT 100 config, status and monitoring. Supports T-Watch PRO.
Single V.35 connector. Supports remote configuration/monitoring
across the FDL or 8K inband. |
|
T1 |
1200060L2 |
Single port T1/FT1
DSU/CSU with metal chassis, LCD display and front panel, 4 button
keypad. VT 100 configuration, status and monitoring. Single V.35 DTE
interface. Supports T-Watch PRO. Supports remote
configuration/monitoring across the FDL or 8K inband. |
|
T1 |
1202077L1 |
2nd Generation
Version of TSU RM rackmount, single port T1/FT1 DSU/CSU for Smart 16
/16e shelf. Similar functionality to standalone TSU. Provides single
V.35 DTE Interface. Integrated Dial Back-up Interface. Remote
management capability via T-WATCH PRO (Inband/8k). |
|
T1 |
1200099L1 |
Rackmount, single
port T1/FT1 DSU/CSU for Smart 16 /16e shelf. Provides single EIA-530
DTE interface. |
|
T1 |
1200169L1 |
Single port T1/FT1
SNMP DSU/CSU, LCD display, VT 100, SNMP and Telnet configuration and
status. Integrated SLIP/PPP port and V.35 DTE connection. Modular
approach with ESP DBU & ESP Ethernet cards. |
|
T1 |
4200169L1 |
TSU ESP (1200169L1)
with 10BaseT Ethernet Card (1204005L1) installed. TSU ESP offers
single port T1/FT1 SNMP DSU/CSU, LCD display, VT 100, SNMP and
Telnet configuration and status. Integrated SLIP/PPP port and V.35
DTE connection. Modular approach with ESP DBU & ESP Ethernet cards. |
|
Category |
Part Number |
Description |
|
T3 |
1200290L1 |
MX2800 Chassis,
does not include any controller cards or power supplies. |
|
T3 |
1202289L1 |
Spare AC Power
supply for MX2800. |
|
T3 |
1200289L2 |
Spare DC Power
supply for MX2800. |
|
T3 |
1202288L2 |
Spare Controller
Card for the MX2800, Incorporates DS3 and 28 DSX-1's. Will work in
either AC or DC versions of the MX2800. Has NO built-in modem. |
|
T3 |
1202288L1 |
Spare Controller
Card for the MX2800, Incorporates DS3 and 28 DSX-1's. Card also
incorporates an integrated modem. Will work in either AC or DC
versions of the MX2800 |
|
T3 |
4202290L1 |
A non-redundant M13
mux that is AC powered and has a built-in V.34 modem for management.
Includes one controller card and one power supply. Unit is 19" or
23" rackmountable and ships w/ one 8-pin to 8-pin modular cable, one
modular to DB-9 female adapter. Unit consist of 1 Chassis
(1200290L1), 1 Controller Card (1202288L1) and 1 AC Power Supply
(1202289L1). |
|
T3 |
4202290L2 |
A fully redundant
M13 mux that is AC powered and has a built-in V.34 modem for
management. Complete w/ redundant controller cards and AC power
supplies. Unit is 19" or 23" rackmountable and ships w/ one 8-pin to
8-pin modular cable, one modular to DB-9 female adapter. Unit
consist of 1 Chassis (1200290L1), 2 Controller Cards (1202288L1) and
2 AC Power Supplies (1202289L1). |
|
T3 |
4202290L3 |
A non-redundant M13
mux that is DC powered and has a built-in V.34 modem for management.
Includes one controller card and one power supply. Unit is 19" or
23" rackmountable and ships w/ one 8-pin to 8-pin modular cable, one
modular to DB-9 female adapter. Unit consist of 1 Chassis
(1200290L1), 1 Controller Card (1202288L1) and 1 DC Power Supply
(1200289L2). |
|
T3 |
4202290L4 |
A fully redundant
M13 mux that is DC powered and has a built-in V.34 modem for
management. Complete w/ redundant controller cards and DC power
supplies. Unit is 19" or 23" rackmountable and ships w/ one 8-pin to
8-pin modular cable, one modular to DB-9 female adapter. Unit
consist of 1 Chassis (1200290L1), 2 Controller Cards (1202288L1) and
2 DC Power Supplies (1200289L2). |
|
T3 |
4202290L5 |
Same as 4202290L1
w/out the built-in modem. Unit consist of 1 Chassis (1200290L1), 1
Controller Card (1202288L2) and 1 AC Power Supply (1202289L1). |
|
T3 |
4202290L6 |
Same as 4202290L2
w/out the built-in modem. Unit consist of 1 Chassis (1200290L1), 2
Controller Cards (1202288L2) and 2 AC Power Supplies (1202289L1). |
|
T3 |
4202290L7 |
Same as 4202290L3
w/out the built-in modem. Unit consist of 1 Chassis (1200290L1), 1
Controller Card (1202288L2) and 1 DC Power Supply (1200289L2). |
|
T3 |
4202290L8 |
Same as 4202290L4
w/out the built-in modem. Unit consist of 1 Chassis (1200290L1), 2
Controller Cards (1202288L2) and 2 DC Power Supplies (1200289L2). |
|
T3 |
4202290L11 |
A non-redundant M13
mux that is AC powered and has a built-in V.34 modem for management.
Includes one controller card and one power supply. Unit is 19" or
23" rackmountable and ships w/ one 8-pin to 8-pin modular cable, one
modular to DB-9 female adapter. Includes built in fan. Unit consist
of 1 Chassis (1200290L1), 1 Controller Card (1202288L1), 1 AC Power
Supply (1202289L1) and 1 Fan Faceplate (1200466L1). Fan allows up to
42 units to be stacked in a 7 foot bay. |
|
T3 |
4202290L12 |
A fully redundant
M13 mux that is AC powered and has a built-in V.34 modem for
management. Complete w/ redundant controller cards and AC power
supplies. Unit is 19" or 23" rackmountable and ships w/ one 8-pin to
8-pin modular cable, one modular to DB-9 female adapter. Include
built in fan. Unit consist of 1 Chassis (1200290L1), 2 Controller
Cards (1202288L1), 2 AC Power Supplies (1202289L1) and 1 fan
faceplate (1200466L1). Fan allows up to 42 units to be stacked in a
7 foot bay. |
|
T3 |
4202290L13 |
A non-redundant M13
mux that is DC powered and has a built-in V.34 modem for management.
Includes one controller card and one power supply. Unit is 19" or
23" rackmountable and ships w/ one 8-pin to 8-pin modular cable, one
modular to DB-9 female adapter. Includes built in fan. Unit consist
of 1 Chassis (1200290L1), 1 Controller Card (1202288L1), 1 DC Power
Supply (1202289L2) and 1 fan faceplate (1200466L1). Fan allows up to
42 units to be stacked in a 7 foot bay. |
|
T3 |
4202290L14 |
A fully redundant
M13 mux that is DC powered and has a built-in V.34 modem for
management. Complete w/ redundant controller cards and DC power
supplies. Unit is 19" or 23" rackmountable and ships w/ one 8-pin to
8-pin modular cable, one modular to DB-9 female adapter. Includes
built in fan. Unit consist of 1 Chassis (1200290L1), 2 Controller
Cards (1202288L1), 2 DC Power Supplies (1202289L2) and 1 fan
faceplate (1200466L1). Fan allows up to 42 units to be stacked in a
7 foot bay. |
|
T3 |
4200290L15 |
Unit consist of 1
Chassis (1200290L1), 1 Controller Card (1200288L2), 1 AC Power
Supply (1202289L1) and 1 fan faceplate (1200466L1). Fan allows up to
42 units to be stacked in a 7 foot bay. |
|
T3 |
4202290L15 |
Same as 4202290L11
w/out the built-in modem. Unit consist of 1 Chassis (1200290L1), 1
Controller Card (1202288L2), 1 AC Power Supply (1202289L1) and 1 fan
faceplate (1200466L1). Fan allows up to 42 units to be stacked in a
7 foot bay. |
|
T3 |
4200290L16 |
Unit consist of 1
Chassis (1200290L1), 2 Controller Cards (1200288L2), 2 AC Power
Supplies (1202289L1) and 1 fan faceplate (1200466L1). Fan allows up
to 42 units to be stacked in a 7 foot bay. |
|
T3 |
4202290L16 |
Same as 4202290L12
w/out the built-in modem. Unit consist of 1 Chassis (1200290L1), 2
Controller Cards (1202288L2), 2 AC Power Supplies (1202289L1) and 1
fan faceplate (1200466L1). Fan allows up to 42 units to be stacked
in a 7 foot bay. |
|
T3 |
4200290L17 |
Unit consist of 1
Chassis (1200290L1), 1 Controller Card (1200288L2), 1 DC Power
Supply (1202289L2) and 1 fan faceplate (1200466L1). Fan allows up to
42 units to be stacked in a 7 foot bay. |
|
T3 |
4202290L17 |
Same as 4202290L13
w/out the built-in modem. Unit consist of 1 Chassis (1200290L1), 1
Controller Card (1202288L2), 1 DC Power Supply (1202289L2) and 1 fan
faceplate (1200466L1). Fan allows up to 42 units to be stacked in a
7 foot bay. |
|
T3 |
4202290L18 |
Same as 4202290L14
w/out the built-in modem. Unit consist of 1 Chassis (1200290L1), 2
Controller Cards (1202288L2), 2 DC Power Supplies (1202289L2) and 1
faceplate fan (1200466L1). Fan allows up to 42 units to be stacked
in a 7 foot bay. |
|
T3 |
4200659L6 |
A fully redundant
STS-1 mux that is AC powered. Complete w/ redundant controller cards
and AC power supplies. Unit is 19" or 23" rackmountable and ships w/
one 8-pin to 8-pin modular cable, one modular to DB-9 female
adapter. Unit consist of 1 Chassis (1200290L1), 2 Controller Cards
(1200659L2) and 2 AC Power Supplies (1202289L1). |
|
T3 |
4200659L8 |
A fully redundant
STS-1 mux that is 48 VDC powered. Complete w/ redundant controller
cards and DC power supplies. Unit is 19" or 23" rackmountable and
ships w/ one 8-pin to 8-pin modular cable, one modular to DB-9
female adapter. Unit consist of 1 Chassis (1200290L1), 2 Controller
Cards (1200659L2) and 2 DC Power Supplies (1200289L2). |
|
T3 |
1200291L1 |
1U high patch panel
that provides 28 RJ connections for DSX-1 deployment. Fits in a 19"
rack. Includes 2 6 foot 64 pin to 64 pin cables to connect directly
to the rear of the MX2800. |
|
T3 |
1200293L1 |
1U extension
bracket, extends 19" rack mount products to 23". Can be used w/
MX2800 RJ Patch Panel (1200291L1) or T3SU (1200217L2 or 1200217L4).
Includes 2 brackets and 4 screws. |
|
T3 |
1200657L2 |
Cable required to
connect to the power and power alarm connectors of the MX2800 and to
the AC/DC Charger (Part # 1175043L2). |
|
T3 |
1200287L1 |
25' cable that
provides a 64 amp on one end for direct connect to the MX2800 and
wire at the other end for connection to a frame or punch down block. |
|
T3 |
4175043L2 |
System includes
battery (1175044L1), charger (1175043L2) and power/alarm cable
(1200657L2). (The battery and charger are the same parts used with
the TA750/TA850.) |
|
T3 |
4200466L1 |
Consist of
Faceplate w/Fan (1200466L1) and 2 AC supplies w/headers (1202289L1).
Allows 42 MX2800s to be stacked in a 7 foot bay. |
|
T3 |
4200466L2 |
Consist of
Faceplate w/Fan (1200466L1) and 2 DC supplies w/headers (1202289L2).
Allows 42 MX2800s to be stacked in a 7 foot bay. |
|
T3 |
1200217L2 |
T3 DSU/CSU for
unchannelized T3 applications. Ability to support up to 4 DTE ports.
Single integrated HSSI port, SCSI-II 50 pin female connector and
three hot swappable option slots. Supports SNMP and Telnet access.
Includes an internal V.34 modem for dial in/dial out configuration
through VT100 or SNMP/Telnet as well as alarm reporting. |
|
T3 |
1200217L4 |
Same as 1200217L2,
but is a DC powered version of product. Uses DC power from 20-60 VDC. |
|
T3 |
1200218L1 |
HSSI interface card
for T3SU 300 and OSU 300. Card provides a 50-pin female connector
and will support rates up to 44.2 Mbps. |
|
T3 |
1200219L1 |
High Speed V.35
interface card for T3SU 300 and OSU 300. Card provides a female V.35
connector and will support rates up to 10 Mbps. |
|
T3 |
1200284L1 |
Quad DSX-1 card
provides 4 DSX-1 ports for a point to point unchannelized T3
application. Up to three quad DSX-1 cards can be used in a T3SU 300
and OSU 300. |
|