THE INFORMATION TECHNOLOGY PRICING SOURCE. Home Site Map About CNP Privacy Policy Faq & Costs CNP Feedback CNP Contact Us

Home
Up
EXTREME APPRAISAL
EXTREME PRICING
EXTREME 3800
EXTREME 6800
EXTREME summit1i
EXTREME summit200
EXTREME summit400-24p
EXTREME summit71
EXTREME summit5i
EXTREME summit 48si
EXTREME summit400-48t
EXTREME summit400-24t
EXTREME summit300-48
EXTREME summit300-24
SUMMIT COMPARISON
EXTREME MODULE LISTING
EXTREME LOCATIONS

 

  

 





APPRAISAL DATA

EXTREME Networksฎ, the leader in open converged networks, offers an end-to end solution that allows you to overcome all these challenges. It comprises Summitฎ fixed configuration switches, Alpine™ chassis-based switches, Aspen™ modular switches, BlackDiamondฎ core switches, wireless products, EXTREMEWareฎ operating systems and EPICenter™ management software. EXTREME products can help you implement the solution to meet your business needs.
CLICK THE PARTS DETECTIVE TO FIND ITEMS YOU WISH TO BUY (THIS SITE DOES NOT SELL PARTS OR SYSTEMS)

 

GET MARKET VALUE OF ANY SINGLE LINE ITEM ON THIS PAGE

BlackDiamond 6800 Series Features
Advanced resiliency and fault tolerance for carrier class performance
•  NEBS level 3 compliance
•  Passive backplane supports redundant, load-sharing,hot-swappable switch fabric modules
•  Hot-swappable I/O modules and fan trays
•  Fully redundant, load-sharing, hot-swappable power supplies
•  IEEE 802.3ad load sharing and redundant PHY
•  Hitless Failover and Hitless Software Upgrade
•  Dual switch configurations and EXTREMEWare images
•  EXTREME Standby Router Protocol (ESRP™) and Virtual Router Redundancy Protocol (VRRP)
•  OSPF Equal Cost Multipath Routing (ECMP)
•  Ethernet Automatic Protection Switching (EAPS)

 


 

Advanced connectivity for scalability and network investment protection
•  Wavelength Division Multiplexing (WDM) optical broadband networking
•  OC-3 and OC-12 packet-over-SONET (PoS)
•  Multi-protocol Label Switching (MPLS)
•  Asynchronous Transfer Mode (ATM)


Extensive management capabilities

 

•  Policy-based Quality of Service, including prioritization, bandwidth management and congestion control
•  Wire-speed server load balancing, web cache redirection, VLAN switching and routing, DiffServ and IEEE 802.1p
•  Management via local and remote (telnet) CLI, SNMP, RMON, and HTTP


Comprehensive security features
 

•  Access Control Lists (ACLs)
•  Access profiles
•  RADIUS
•  SSH2
•  Network-Login


Industry-leading performance
 

•  Wirespeed IP/IPX routing
•  Wirespeed switching
•  4,096 IEEE 802.1Q VLANs
•  Switch and route jumbo frames


BlackDiamond 6804

 

10 Gigabit Ethernet
•  Up to 4 ports when fully populated with the 10GX3 module.
Gigabit Ethernet
•  32 1000BASE-X ports when fully populated with the G8Xi module.
•  32 100/1000BASE-T ports when fully populated with the G8Ti module.
•  48 1000BASE-SX ports when fully populated with the G12Sxi module.
•  64 1000BASE-X ports when fully populated with the G16X3 module.
•  96 10/100/1000BASE-T ports when fully populated with the G24T3 module.
Fast Ethernet
•  192 10/100BASE-TX ports when fully populated with the F48Ti module.
•  384 10/100BASE-TX ports when fully populated with the F96Ti module.
•  128 100BASE-FX ports when fully populated with the F32Fi module.
PoS and ATM
•  OC-12: Up to 8 ports when fully populated with the P12cSi or P12cMi modules.
•  OC-3: Up to 16 ports when fully populated with the P3cSi, P3cMi, A3cSi, or A3cMi modules.


BlackDiamond 6808

 

10 Gigabit Ethernet
•  Up to 8 ports when fully populated with the 10GX3 module.
Gigabit Ethernet
•  64 1000BASE-X ports when fully populated with the G8Xi module.
•  64 100/1000BASE-T ports when fully populated with the G8Ti module.
•  96 1000BASE-SX ports when fully populated with the G12SXi module.
•  128 1000BASE-X ports when fully populated with the G16X3 module.
•  168 10/100/1000BASE-t ports when fully populated with the G24T3 module
Fast Ethernet
•  384 10/100BASE-TX ports when fully populated with the F48Ti module.
•  672 10/100BASE-TX ports when fully populated with the F96Ti module.
•  256 100BASE-FX ports when fully populated with the F32Fi module.
PoS and ATM
•  OC-12: Up to 16 ports when fully populated with the P12cSi or P12cMi modules.
•  OC-3: Up to 32 ports when fully populated with the P3cSi, P3cMi, A3cSi, or A3cMi modules.


BlackDiamond 6816

10 Gigabit Ethernet
•  Up to 16 ports when fully populated with the 10GLX3 module.
Gigabit Ethernet
•  128 1000BASE-X ports when fully populated with the G8Xi module.
•  128 100/1000BASE-T ports when fully populated with the G8Ti module.
•  192 1000BASE-SX ports when fully populated with the G12SXi module.
•  256 1000BASE-X ports when fully populated with the G16X3 module.
•  360 10/100/1000BASE-T ports when fully populated with the G24T3 module.
Fast Ethernet
•  768 10/100BASE-TX ports when fully populated with the F48Ti module.
•  1440 10/100BASE-TX ports when fully populated with the F96Ti module.
•  512 100BASE-FX ports when fully populated with the F32Fi module.
PoS and ATM
•  OC-12: Up to 32 ports when fully populated with the P12cSi or P12cMi modules.
•  OC-3: Up to 64 ports when fully populated with the P3cSi, P3cMi, A3cSi, or A3cMi modules.


 

BlackDiamond 6800 Series Product Specifications
Performance
BlackDiamond 6804
•  256 Gbps total switching capacity Route/ filter/ forward 48 million pps
BlackDiamond 6808
•  384 Gbps total switching capacity Route/ filter/ forward 96 million pps
BlackDiamond 6816
•  768 Gbps total switching capacity Route/ filter/ forward 192 million pps
Protocols and Standards
RIP
• 
RFC 1058 RIP v1
•  RFC 1058 RIP v2
OSPF
•  RFC 2328 OSPF v2 (including MDS authentication)
•  RFC 1587 OSPF NSSA Option
•  RFC 1765 OSPF Database Overflow
•  2370 OSPF Opaque LSA Option
BGP4
•  RFC 1771 Border Gateway Protocol 4
•  RFC 1965 Autonomous System Confederations for BGP
•  RFC 1966 BGP Route Reflection
•  RFC 1997 BGP Communities Attribute
•  RFC 1745 BGP/OSPF Interaction
•  RFC 2385 TCP MDS Authentication for BGPv4
IP Multicast
•  RFC 2362 PIM-SM
•  PIM-DM Draft IETF PIM-Dense Mode v2-dm-03
•  DVMRP v3 Draft IETF DVMRP v3-07
•  RFC 1112 IGMPv1
•  RFC 2236 IGMP v2
•  IGMP snooping with Configurable Router Registration Forwarding
10 GBE
•  IEEE 802.3ae 10 Gigabit Ethernet
•  IEEE 802.3x Flow Control (pause frames)
ATM
•  RFC 1483/2584 multi-protocol encapsulation over ATM AAL-5
•  ATM PVC to 802.1Q tag mapping
MPLS
•  RFC 3031 Multi-Protocol Label Switching architecture
•  RFC 3032 MPLS label stack encoding
•  RFC 3036 LDP specification
•  draft-martini-12 circuit-encap-mpls-08 transport of Layer 2 frames over MPLS
•  draft-ietf-mpls-diff-ext-09 MPLS support of DiffServ
•  RFC, 2961 RSVP refresh overhead reduction extension
•  draft-ietf-mpls-rsvp-Isp-tunnel-09 RSVP-TE: extension to RSVP for
LSP tunnels
•  RFC 2211 controlled load network element service
•  RFC 2702 requirements for traffic engineering over MPLS
General Routing/Switching
•  RFC 1812 IPv4 Router Requirements
•  RFC 1519 CIDR
•  RFC 1256 IRDP Router Discovery
•  RFC 783 TFTP
•  RFC 951, 1542 BootP
•  RFC 2131 BOOTP/DHCP Helper
•  RFC 1591 DNS (client operation)
•  RFC 1122 Host Requirements
•  RFC 768 UDP
•  RFC 791 IP
•  RFC 792 ICMP
•  RFC 793 TCP
•  RFC 826 ARP
•  RFC 2338 VRRP
•  EXTREME Standby Router Protocol(ESRP)
•  IPX RIP/SAP Router specification
•  IEEE802.1D-1998 Spanning Tree Protocol
•  IEEE 802.1Q - 1998 Virtual Bridged Local Area Networks
•  Ethernet Automatic Protection Switching (EAPS)
•  Multiple Instances of Spanning Tree (PVST, 802.1Q interoperable)
•  Software controlled redundant ports
Management and Security
Management - SNMP & MIBs
•  RFC 1155 Structure of Mgmt Information (SMIv1)
•  RFC 1157 SNMP v1/v2c
•  RFC-1212, RFC-1213, RFC-1215 MIP-II & TRAPs
•  RFC 1901 - 1907 SNMP Version 2c, SMIv2 and Revised MIB-II
•  RFC 1757 RMON 4 groups; Statistics, History, Alarms, and Events
•  RFC 2021 RMON2 (probe configuration)
•  RFC 2613 SMON MIB
•  RFC 2668 802.3 MAU MIB
•  RFC 1643 Ethernet MIB
•  RFC 1650 Etherlike-MIB
•  RFC 1573 Evolution of Interface
•  RFC 1493 Bridge MIB
•  RFC 1354 IPv4 Forwarding Table MIB
•  RFC 2037 Entity MIB RFC 2233 Interface MIB
•  RFC 2096 IP Forwarding
•  RFC 1724 IPv2 MIB
•  RFC 1850 OSPFv2 MIB
•  RFC 1657 BGPv4 MIB
•  RFC 2787 VRRP MIB
•  RFC 2925 Ping/Traceraoute/NSLOOKUP MIB
•  EXTREMEWare vendor MIB (includes ACL, MAC FDB, IP FDB, QoS policy and VLAN config)
Management - Other
•  RFC 1866 HTML
•  RFC 2068 HTTP
•  RFC 854 Telnet
•  HTML/HTTP management
•  Secure Shell (SSHv2) and Telnet management, Telnet and SSHv2 clients
•  Secure Copy (SCPvw)
•  NetFlow version 1 export
•  Configuration logging
•  Multiple Images, Multiple Configs
•  BSD System Logging Protocol (SYSLOG), with Multiple Syslog Servers
•  999 Local Messages (criticals stored across reboots)
•  RFC 2030 Siimple Network Time Protocol v4
Security
•  Routing protocol authentication (see above)
•  Secure Shell (SSHv2) & Secure Copy (SCPv2) with encryption/authentication
•  RFC 1492 TACACS+
•  RFC 2138 RADIUS Authentication
•  RFC 2139 RADIUS Accounting
•  RADIUS Per-command Authentication
•  Access Profiles on All Routing Protocols
•  Access Profiles on All Management Methods
•  Network Login (including DHCP/RADIUS integration)
•  MAC Address Security/Lockdown
•  Network Address Translation (NAT)
•  Layer 2/3/4/7 Access Control Lists (ACLs)
Denial of Service Protection
•  RFC 2267 Network Ingress Filtering
•  RPF (Unicast Reverse Path Forwarding) Control
•  Wire-speed ACLs
•  Rate Limiting by ACLs
•  IP Broadcast Forwarding Control
•  ICMP and IP_Option Response Control
•  Server Load Balancing with Layer 3, 4 Protection of Servers
•  SYN attack protection
•  Uni-directioinal Session Control
Safety Standards
•  UL 1950 3rd Edition, Listed (Safety of ITE)
•  cULus Listed Equivalent to CAN/CSA-22.2 No. 950-M93 (Canadian Safety of ITE)
•  Low Voltage Directive (LVD) (European Safety Directive)
•  CB Report and Certificate (International Safety of ITE)
•  IEC60950:1991/A1-4 2nd Edition (European Safety of ITE)
•  TUVGS Mark (German Notified Body)
•  EN60950:1992/A1-4,A11+ Deviations (European Safety of ITE)
•  AS/NZS 3260 (Australia Safety Standard)
•  S Mark (Argentina Safety Approval)
•  GOST (Russian Federation Certificate)
•  Laser Devices
•  EN60825-1,2:1994,A11:1996 (European Safety of Lasers Products)
•  FCC21 CFR Subpart J(US Safety of Laser Products)
•  CDRH Letter of Approval (US FDA Approval)
 
 

EMI/EMC Standards

•  FCC CFR 47 part 15 Class A (US Emissions)
•  ICES-003A/C108.8-M1983 Class A (Canada EMC standard)
•  89/336/EECEMC Directive (European Requirements)
•  CISPR22:1997 Class A (International Emissions)
•  EN55022:1998 Class A (European Emissions)
•  EN55024:1998 includes EN61000-4-2,3,4,5,6,8,11 (European Immunity)
•  EN610000-3-2,3 (European Harmonics & Flicker)
•  AS/NZS 35-48 (Australia Emissions)
•  VCCI Class A (Japan Emissions)
•  CNS 13438:1997 Class A (Taiwan Emisisons)
•  MIC Mark (Korean Emissions & Immunity Approval)
•  NOM/NYCE (Mexican Product Saftey & EMC Authorities)
•  Telcordia GR-1089 (Bellcore Emissions & Immunity Standard)
Telecom Standards
•  EN300386-2 v1.1.3 (1997-12) (European Telecom Standard)
•  NEBS Type IV, Level 3 (US Voluntary Telecom Standard)
•  Additional Telecom Approvals held on Individual Blades
Environmental Standards
•  EN600068 to EXTREME IEC68 schedule
•  ETS 300 019 to EXTREME schedule
•  Telcordia GR-3-Core (Bellcore Environmental & Safety Standard)
Physical Dimensions (Approximate)
BlackDiamond 6804
•  (H) 19.25 in x (W) 17.32 in x (D) 19 in
•  (H) 48.89 cm x (W) 43.99 cm x (D) 48.26 cm
•  Weight - Empty: 57.5 lbs (26.1 kg)
•  Weight - Full: 161 lbs (73 kg)
BlackDiamond 6808
•  (H) 26.25 in x (W) 17.32 in x (D) 18 in
•  (H) 66.68 cm x (W) 43.99 cm x (D) 45.72 cm
•  Weight - Empty: 60 lbs (27 kg)
•  Weight - Full: 188 lbs (85.3 kg)
BlackDiamond 6816
•  (H) 61.25 in x (W) 19 in x (D) 19 in
•  (H) 155.57 cm x (W) 48.25 cm x (D) 48.26 cm
•  Weight - Empty: 75.4 lbs (34.2 kg)
•  Weight - Full: 332 lbs (150.6kg)
Full indicates chassis with 2 to 4 PSUs and all slots are full with modules
 

Operating Specification

•  Operating temperature 0 to 40C
•  Storage temperature -40 to 70C
•  Operating humidity 10% to 95% relative humidity, non-condensing
•  EN60068 to EXTREME IEC68 schedule
 

Reliability

•  Minimum 50000 hrs MTBF to Mil HDBK-217F Notice 1, Parts Stress Method