Juniper Networks M-series Multi-service Edge Routing Portfolio

Edge Routing with the M-series from Juniper Networks
 
CLICK THE PARTS DETECTIVE TO FIND ITEMS YOU WISH TO BUY (THIS SITE DOES NOT SELL PARTS OR SYSTEMS)

Specifications

Physical
Description M7i M10i M20 M40e M320
Dimensions
(H x W x D)
3.5 x 17.5 x 18 in
8.9 x 44.5 x 45.7 cm
8.75 x 17.5 x 18 in
22.2 x 44.5 x 45.7 cm
14 x 17.4 x 21 in
35.6 x 44.3 x 53.3 cm
35 x 17.4 x 26 in
88.9 x 44.3 x 73.7 cm
34.8 x 17.4 x 25.7 in
88.4 x 44.3 x 65.1 cm
Maximum Weight 38.2 lbs / 17.3 Kg 79 lbs / 36 Kg 150 lbs / 68 kg 370.5 lbs / 168 kg 439 / 199.6 kg
Mounting Front or center Front or center Front or center Front or center Front or center
DC System Input Power (Fully Loaded)
  10 A at –48 VDC
378 watts
12 A at –48 VDC
576 watts
24 A at -48 VDC
1,200 watts
54 A at -48 VDC
2,600 watts
65 A at -48 VDC
3,150 watts
DC Input Power Supply (per individual power supply)
Nominal Voltage -48, -60 VDC -48, -60 VDC -48, -60 VDC -48, -60 VDC -48, -60 VDC
Operating Range -42 to -72 VDC -42 to -72 VDC -42 to -72 VDC -42 to -72 VDC -42 to -72 VDC
Power 378 watts 576 watts 1,200 watts 3,150 watts 2,000 watts
Current Rating 10 A at –48 VDC 12 A at –48 VDC 24 A at -48 VDC 65 A at -48 VDC* 42A at -48 VDC
# of power supplies required (non-redundant/ redundant) 1/2 2/4 1/2 1/2 2/4
AC System Input Power (Fully Loaded)
  4 to 2 A
00 to 240 VAC
47 to 63 Hz
400 watts
8 to 4 A
100 to 240 VAC
47 to 63 Hz
800 watts
12 to 6 A
200 to 240 VAC
47 to 63 Hz
1,950 watts
15 to 13 A
200 to 240 VAC
47 to 63 Hz
3,000 watts
17 A to 14 A 200 to 240 VAC47-63 Hz
3,500watts
AC Input Power Supply (per individual power supply)
  100, 120, 200, 208, 220, 240 VAC 100, 120, 200, 208, 220, 240 VAC 100, 120, 200, 208, 220, 240 VAC 200, 208, 220, 240 VAC 200,208,220, 240 VAC
Operating Range 90 to 264 VAC 90 to 264 VAC 90 to 264 VAC 180 to 264 VAC 180 to 264 VAC
Power 400 watts 800 watts 1,200 watts 3,000 watts 1,750 watts
Current Rating 4 to 2 A
100 to 240 VAC
8 to 4 A
100 to 240 VAC
12 to 6 A
100 to 240 VAC
16 A
200 to 240 VAC
10 to 8.5 A200 to 240 VAC
# of power supplies required (non-redundant/ redundant) 1/2 2/3 1/2 1/2 3/4
 

* The M40e router does not require circuit breakers greater than 60 A, and does not draw greater input current than 54 A.
* The depth of all chassis are measured from the front flange to the rear of the product. Please add 4-6" for cables and airflow clearance.

Forwarding and Switch Interface Boards

M7i, M10i CFEB

Compact Forwarding Engine Board

bulletM7i router
bullet8.4 Gbps throughput rate (4.2-Gbps full duplex)
bulletOptional Adaptive Services Module
bulletM10i router
bullet12.8-Gbps throughput rate (6.4-Gbps full duplex)
bulletDoes not support Adaptive Services Module
bullet266-MHz CPU and supporting logic
bulletInternet Processor II-based ASIC for 16-Mpps packet lookup
bulletTwo enhanced I/O Manager ASICs
bulletParsing, prioritizing, and queuing of packets
bullet4-MB parity-protected SSRAM per I/O Manager ASIC
bullet8-MB SSRAM for forwarding tables associated with ASICs
bullet200 ms of delay-bandwidth buffering
bulletTwo 512-KB boot flash EPROM (programmable on the board)
M20 SSB

System and Switch Board

bullet25.6-Gbps throughput (12.8-Gbps full duplex)
bulletOne Internet Processor II ASIC for 40-Mpps packet lookup
bulletTwo Distributed Buffer Manager ASICs for coordinating pooled, single-stage buffering
bullet33-MHz PCI bus, which connects the PowerPC 603e processor and the Internet Processor II ASIC
bullet512-KB boot flash EPROM (programmable on the board)
bulletOptional redundancy
bullet16-MB Version
bulletPowerPC 603e processor running at 266 MHz for handling exception packets
bullet16-MB SSRAM
bullet256-MB DRAM
M40e SFM

Switching and Forwarding Module

bullet51.2-Gbps throughput (25.6-Gbps full duplex)
bulletOne Internet Processor II ASIC for 40-Mpps aggregate packet lookup
bulletTwo Distributed Buffer Manager ASICs for coordinating pooled, single-stage buffering
bullet256-KB parity-protected Level 2 cache
bulletOptional redundancy
bullet16-MB Version
bulletPowerPC 603e processor running at 266 MHz
bullet16-MB parity-protected SSRAM
bullet256-MB parity-protected DRAM
M320 SIB

Switch Interface Board for interconnecting FPCs

bulletFour required per M320 chassis; all four active
bullet80-Gbps throughput per SIB, 320 Gbps throughput per system
bulletProcessor subsystem 300-MHz CPU
bulletSystem controller
bullet256-MB DRAM
bulletTwo Fast Ethernet interfaces
FPC
M20
bullet3.2-Gbps full-duplex throughput per FPC
bulletEnhanced I/O Manager ASIC
bulletParsing, prioritizing, and queuing of packets
bullet2-MB parity-protected SSRAM per I/O Manager ASIC
bullet200 ms of delay-bandwidth buffering per FPC
M40e
bullet3.2-Gbps full-duplex throughput per M40e-FPC, M40e-FPC1, and M40e-FPC2
bulletTwo Packet Director ASICs for dispersing and balancing packets across the enhanced I/O Manager ASICs
bulletTwo enhanced I/O Manager ASICs
bulletParsing, prioritizing, and queuing of packets
bullet2-MB parity-protected SSRAM per I/O Manager ASIC
bullet200 ms of delay-bandwidth buffering per FPC
M320
bullet4-Gbps full-duplex throughput per M320-FPC1
bullet16-Gbps full-duplex throughput per M320-FPC2
bullet20-Gbps full-duplex throughput per M320-FPC3
bulletLayer 2 / Layer 3 Packet Processing ASICs
bulletSwitch Interface ASICs
bulletInternet Processor ASICs
bulletMemory subsystem, including Queuing and Memory Interface ASICs
bulletProcessor subsystem
Routing Engine
400 MHz (M7i, M10i)
bullet400-MHz Celeron processor with default 256-KB Level 2 cache
bullet256-MB SDRAM DIMMs, upgradeable to 512-MB or 768-MB SDRAM in 256-MB increments
bullet20-GB IDE hard drive for secondary storage
bulletFast Ethernet RJ-45 port for out-of-band management
bulletTwo RS-232 (DB-9 connector) asynchronous serial ports for console and remote management
bulletBackup boot media
bulletOptional PCMCIA card adapter and 256-MB compact flash card
600 MHz (M20, M40e)
bullet600-MHz Intel Pentium III
bulletMemory
bulletM20, M40e: 2-GB ECC DRAM
bullet256-MB flash drive for primary storage
bullet30-GB IDE hard drive for secondary storage
bulletTertiary storage
bulletM20, M40e: 128-MB flash PC card
1.6 GHz (M320)
bullet1.6-GHz Pentium IV processor with integrated 256-KB Level 2 cache
bullet2-GB DRAM
bullet256-MB Compact flash drive for primary storage
bullet30-GB IDE hard drive for secondary storage
bullet10/100 Base-T autosensing RJ-45 Ethernet port for out-of-band management
bulletTwo RS-232 (DB9 connector) asynchronous serial ports for console and remote management
bulletOptional redundancy
Control Systems
M40e

Miscellaneous Control Subsystem

bullet19.44-MHz stratum 3 reference clock for PICs
bulletController to monitor the status of router components
M320

Control Board

bulletProvides buses and control processors used for chassis management
bullet10/100Base-T/TX Ethernet switch for intermodule communication
bulletProcessor subsystem
bulletTwo external clock inputs for 19.44-MHz stratum 3 reference clock
bulletOptional redundancy
Agency Approvals
Safety
bulletCAN/CSA-C22.2 No. 60950-00/UL 60950—Third Edition, Safety of Information Technology Equipment
bulletEN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User's Guide
bulletEN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems
bulletEN 60950 Safety of Information Technology Equipment
EMC (M20, M40e, M320)
bulletAS/NZS 3548 Class A (Australia / New Zealand)
bulletBSMI Class A (Taiwan)
bulletEN 55022 Class A Emissions (Europe)
bulletFCC Part 15 Class A (USA)
bulletVCCI Class A (Japan)
EMC (M7i, M10i)
bulletAS/NZS 3548 Class B (Australia / New Zealand)
bulletBSMI Class B (Taiwan)
bulletEN 55022 Class B Emissions (Europe)
bulletFCC Part 15 Class B (USA)
bulletVCCI Class B (Japan)
Immunity
bulletEN 61000-3-2 Power Line Harmonics
bulletEN 61000-4-2 ESD
bulletEN 61000-4-3 Radiated Immunity
bulletEN 61000-4-4 EFT
bulletEN 61000-4-5 Surge
bulletEN 61000-4-6 Low Frequency Common Immunity
bulletEN 61000-4-11 Voltage Dips and Sags

NEBS

M7i, M10i, M20, M40e: Compliant
M320: Designed to meet these standards

bulletGR-63-Core: NEBS, Physical Protection
bulletGR-1089-Core: EMC and Electrical Safety for Network Telecommunications Equipment
bulletSR-3580 NEBS Criteria Levels (Level 3 Compliance)
ETSI
bulletETS-300386-2 Telecommunication Network Equipment Electromagnetic Compatibility Requirements
Environment
Temperature
bullet32 to 104 degrees F / 0 to 40 degrees C
Maximum Altitude
bulletNo performance degradation to 10,000 ft / 3,048 m
Relative Humidity
bullet5 to 90 percent noncondensing
Seismic / Earthquake
bulletDesigned to meet Telecordia Technologies Zone 4 earthquake requirements
  

         

 

 